In addition, the voltage and current controllers, the synchronize reference frame theory (SRFT)-based approach, and the phaselocked loop (PLL) control algorithms are embedded in dSPACE 1104 control platform. A various hardware circuits including signal sensing circuit, signal conditioning circuit, pulse amplification and isolation circuit, and blanking circuit are fabricated and assembled to develop a complete laboratory prototype model. This typically includes source current harmonic attenuation, load reactive current mitigation, neutral current elimination, source current balancing, in addition to ensure unity power factor operation. multifunctional inverter controlled SPV system proposed in this work not only injects active power into the electric grid, but it also serves as an active power filter (APF) to provide various power quality (PQ) solutions. Since the inverter is considered as a key constituent of an SPV system, a laboratory developed three-phase four-legged (3P4L) inverter is employed to diminish the overall cost of the SPV system considerably. In this paper, a detailed documentation revealing the design, development, and implementation aspects of grid-connected solar photovoltaic (SPV) power conversion system is presented. Simulation and experimental results show that the proposed method has good tracking performance and robustness to motor parameter perturbation. Finally, a simulation model of Matlab/Simulink and a hardware-in-the-loop simulation platform based on dSPACE were built. Then, the phase-locked loop calculated the rotor speed and position based on the fundamental back-EMF. Secondly, using the position signal calculated by the phase-locked loop as the reference, the filter adjusted the band-pass cut-off frequency adaptively, filtered out a large amount of buffeting and harmonics in the back electromotive force, and output the fundamental back-EMF synchronously. electromotive force (back-EMF) was obtained. Firstly, based on the mathematical model of the motor, the sliding mode current observer was constructed and the back. In order to accelerate the speed and improve the position observation performance of surface-mounted permanent-magnet synchronous motor (SM-PMSM), a sliding mode observer (SMO) was proposed combined with adaptive synchronization filter (ASF) and quadrature phase lock loop (PLL). Atrakcyjność przedstawianego artykułu podnosi zastosowanie autorskiego emulatora sieci elektroenergetycznej. Przedstawione zostaną wyniki badań algorytmu PLL symulowanego w środowisku Matlab/Simulink oraz zostanie dokonane porównanie wyników symulacyjnych z wynikami uzyskanymi podczas badania rzeczywistego przekształtnika współpracującego z modelem sieci. W artykule autor skupia się na niezwykle istotnym elemencie systemu przekształtnikowego jakim jest algorytm synchronizacji falownika z siecią (PLL). Takie działania prowadzą do efektywnego przekształcania energii elektrycznej oraz bezpiecznej pracy nawet podczas silnych zakłóceń pochodzących od sieci elektroenergetycznej. poprzez stosowanie złożonych algorytmów sterowania wektorowego). W tym celu należy maksymalizować sprawność układów przekształtnikowych oraz dostosować do pracy z dynamicznie zmieniającymi się parametrami sieci elektroenergetycznej (np. Efektywne wykorzystanie źródeł energii odnawialnej jest zagadnieniem coraz częściej poruszanym, z uwagi na rosnące wymagania stawiane przez użytkowników, głównie pod kątem czasu zwrotu inwestycji oraz niezawodności komponentów wchodzących w skład systemu.
0 Comments
Leave a Reply. |